Human-Machine Interfaces(HMIs)-GOT GOT SIMPLE Series
Add value to your installation and machine
Security with password management
Operator authentication function
Setting the operation authority and the viewing authority per operator achieves “enhanced security” and “prevention of improper operation”. Operator authentication can be performed at startup and when the screen is switched.
Reduce risk of unauthorized access through network
IP filter function
Registering the IP address of the device which can access the GOT restricts the access from unauthorized devices.
Register the IP address of the device to allow access
Register the IP address of the device to prohibit access
Easily exchange data with FTP
File transfer function
By using GOT, production results and alarm logs can be stored in an SD memory card of the GOT (FTP client) and sent to a personal computer (FTP server). The GOT can also receive the production instruction data from the personal computer.
By using the GOT as an FTP server, files can be read to and written from the personal computer that acts as an FTP client. (FTP server function)
Writing file from GOT to personal computer
Reading file from personal computer to GOT
Setting multiple functions with one switch
Multi-action switch function
Multiple functions can be set to one switch, so there is no need for multiple switches for separate functions. By setting execution sequence and conditions, delay, repeat, interlock settings can be combined, reducing the burden of programmable controller programming.
Language change according to country of the operator
Language switching
Screen can be easily made for switching between Japanese, Chinese, English, etc. 30 languages can be set for each comment.
Screens, not only languages, can be switched based on purpose.
Easily installed on compact equipment
Vertical display
By using a GOT vertically, it can be easily installed on compact equipment and can neatly display vertical letters.
Less scrolling is needed when displaying lists.
Saving energy when operator is not present
Screen saver function
Screen save time can be set from 1 to 60 minutes. By setting the backlight ON/OFF, energy can be saved when no operator is present.
Programmable controller can also control the ON/OFF status, so the backlight will turn ON and alarm screen will display when an alarm occurs.